Investigation Report

Falling Casing Struck Tongs During Casing Handling

BSEEBureau of Safety and Environmental Enforcement

08-16-2012 12:50 G33640 SS / 121 Required Evacuation / LTA (>3Days) / Draw Works

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a casing-handling accident on Hercules 205. Elevators lodged in the derrick A-frame, and continued pulling caused sling and swivel failure. Falling casing struck tongs, displacing the operator from his platform and breaking his neck. The pre-job analysis identified the snagging hazard, but nobody was assigned to watch for it.

Topics

About This Record
Original title
08-16-2012 12:50 G33640 SS / 121 Required Evacuation / LTA (>3Days) / Draw Works
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Dropped Objects, Falls from Height, Line of Fire, Mechanical Failure
Activity
Drilling, Lifting Operations, Rigging
Equipment
Lifting Accessories
Control
Job Safety Analysis
Sector
Upstream Oil and Gas