Investigation Report

Subsea Oil Leak from Riser Touchdown Connector

BSEEBureau of Safety and Environmental Enforcement

06-08-2022 1310 G09868 MC 778 A Pollution

Read at BSEEOpens the document on bsee.gov

Summary

BSEE investigates a subsea oil leak from Thunder Horse’s P2 riser touchdown connector, with pollution estimated at 12.8–128.1 gallons. The report examines connector failure, ROV observations and limitations of pressure-trend leak detection, alongside well shut-in, gasket resealing, pressure testing and interim flowline maintenance pending replacement.

Topics

About This Record
Original title
06-08-2022 1310 G09868 MC 778 A Pollution
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Environmental Protection, Hydrocarbon Release, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Process Pipework and Pipelines
Control
Energy and Process Isolation, Preventive Maintenance
Sector
Upstream Oil and Gas
Setting
Subsea
Link
Checked , working
Record
bsee-4ec3724a04 · added 2 October 2026