Investigation Report

Compressor Fire Following Rod-Bearing Replacement

BSEEBureau of Safety and Environmental Enforcement

11-09-2010 06:00 G02968 MC/311 Fire - Other

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a compressor fire on Mississippi Canyon Platform A following rod-bearing replacement. A stuck-open fuel valve allowed exhaust gas into the fuel line; heat and vibration separated a coupling, igniting its contents. The report describes emergency shutdown, firefighting, and corrective installation of temperature monitoring and flexible hoses.

Topics

About This Record
Original title
11-09-2010 06:00 G02968 MC/311 Fire - Other
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Hydrocarbon Release, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Hose, Process Pipework and Pipelines, Valve
Control
Emergency Response, Fire Protection
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-698f7a0b94 · added 2 October 2026