Investigation Report

Vessel Listing and Flooding Following Hurricane Evacuation

BSEEBureau of Safety and Environmental Enforcement

07-08-2005 15:25 G09868 MC/778 Incident >$25K - Ballast Control Failure

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of vessel listing and flooding following evacuation for Hurricane Dennis. Ineffective hydraulic isolation allowed ballast and bilge valves to open, enabling water migration. Faulty check valves and failed bulkhead cable transits worsened flooding. Recommendations address isolation procedures, HAZOP review, watertight integrity inspections and remote ballast control.

Topics

About This Record
Original title
07-08-2005 15:25 G09868 MC/778 Incident >$25K - Ballast Control Failure
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Loss of Vessel Stability, Mechanical Failure, Vessel Flooding and Foundering
Activity
Inspection and Maintenance, Marine Operations
Equipment
Valve
Control
Flood Containment and Watertight Integrity, Energy and Process Isolation, Operating and Work Procedures, Risk Assessment
Setting
Vessel