Investigation Report
Vessel Listing and Flooding Following Hurricane Evacuation
07-08-2005 15:25 G09868 MC/778 Incident >$25K - Ballast Control Failure
- BSEE
- Investigation Report
- Unknown
- Loss of vessel stabilityMechanical failureVessel flooding and foundering
- Inspection and maintenanceMarine operations
- Valve
- Flood containment and watertight integrityEnergy and process isolationOperating and work proceduresRisk assessment
- Vessel
Summary
Investigation of vessel listing and flooding following evacuation for Hurricane Dennis. Ineffective hydraulic isolation allowed ballast and bilge valves to open, enabling water migration. Faulty check valves and failed bulkhead cable transits worsened flooding. Recommendations address isolation procedures, HAZOP review, watertight integrity inspections and remote ballast control.
Classifications: Loss of vessel stability; capsize; vessel stability.
Classifications: Mechanical failure; equipment failure.
Classifications: Vessel flooding and foundering; water ingress.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Marine operations; maritime operations.
Classifications: Valve; valves.
Classifications: Flood containment and watertight integrity.
Classifications: Energy and process isolation; isolation; energy isolation.
Classifications: Operating and work procedures.
Classifications: Risk assessment; hazard assessment.