Investigation Report

Fuel Gas Filter Fire During Restart After Shut-In

BSEEBureau of Safety and Environmental Enforcement

05-09-2015 17:30 G06280 EB 165 A Shutdown from Gas Release / Fire / Incident >$25K /Required Muster

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a fuel-gas filter fire at EB 165A during restart after a shut-in. Overpressurisation expelled the vessel top, which struck a handrail and ignited escaping gas. Findings identify corroded securing tabs, malfunctioning pressure safety valves and vessel modifications. Operators extinguished the fire while other personnel mustered.

Topics

About This Record
Original title
05-09-2015 17:30 G06280 EB 165 A Shutdown from Gas Release / Fire / Incident >$25K /Required Muster
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Corrosion, Fire, Hydrocarbon Release, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Pressure Vessel, Valve
Control
Emergency Response, Fire Protection, Functional Testing, Pressure Relief
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-7dba26be06 · added 2 October 2026

Report a problem with this record