Investigation Report

Gas Release and Water Hammer Following Compressor Shutdown

BSEEBureau of Safety and Environmental Enforcement

02-28-2007 20:14 G15610 GC/782 Required Muster - Shutdown from Gas Release

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a gas release at Mad Dog following compressor shutdown. Flare backpressure caused tandem rupture discs to fail, allowing gas into seawater cooling pipework and causing water hammer and damage. The report examines earlier failures and recommends check valves, revised pressure protection, flare modifications and delayed seawater pump shutdown.

Topics

About This Record
Original title
02-28-2007 20:14 G15610 GC/782 Required Muster - Shutdown from Gas Release
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Hydrocarbon Release, Mechanical Failure, Pressure Systems
Equipment
Gas Detector, Process Pipework and Pipelines, Pumps, Rotating Machinery, Valve
Control
Emergency Response, Pressure Relief
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-bbc2a85680 · added 2 October 2026