Investigation Report

Flash Fire During Well Abandonment Cutting Operations

BSEEBureau of Safety and Environmental Enforcement

09-07-2007 16:30 00438 EI/175 Required Evacuation - Other Injury - Fire

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a flash fire during well abandonment on Eugene Island Platform F. Gas and condensate travelled through shared pressure-relief piping to an unblinded flowline and ignited at a cutting torch, injuring a welder. Findings address a leaking wing valve, inadequate isolation and joint job safety analysis.

Topics

About This Record
Original title
09-07-2007 16:30 00438 EI/175 Required Evacuation - Other Injury - Fire
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Hydrocarbon Release, Mechanical Failure, Pressure Systems
Activity
Hot Work, Well Abandonment
Equipment
Process Pipework and Pipelines, Valve
Control
Ignition Source Control, Energy and Process Isolation, Job Safety Analysis, Pressure Relief
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-2bf48309e4 · added 2 October 2026