Safety Alert 3 - Flash Fire, Glycol Gas Dehydrator Unit

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 3

Safety Alert 3 - Flash Fire, Glycol Gas Dehydrator Unit

Read at BSEEOpens the document on bsee.gov

Summary

A gas production platform flash fire followed a fatigue crack in threaded glycol return pipework. Released gas and condensate ignited on an uninsulated reboiler stack. Vibration was identified as the probable fatigue cause. Recommendations address vibration damping, periodic pipework inspections and insulation or double-wall exhaust stacks at potential ignition sources.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 3
Date
3 January 1973 (added from another catalogue record)
Topic
Fire, Hydrocarbon Release, Material Fatigue
Activity
Inspection and Maintenance
Equipment
Process Pipework and Pipelines
Control
Ignition Source Control, Preventive Maintenance
Sector
Upstream Oil and Gas
Setting
Offshore Installation