Investigation Report

Two Hydraulic Boom Cylinder Failures on a Crane

BSEEBureau of Safety and Environmental Enforcement

04-25-2018 17:00 G05431 VR 252 A Crane - Equipment Failure

Read at BSEEOpens the document on bsee.gov

Summary

An investigation examines two hydraulic boom cylinder failures on a crane at Vermilion 252-A. Inferior refurbished welds and mismatched working strokes were identified as causes. Dye penetrant testing had not detected the weld defects. Operators should consider paired replacement when one cylinder needs repair, or verify matching cylinder dimensions.

Topics

About This Record
Original title
04-25-2018 17:00 G05431 VR 252 A Crane - Equipment Failure
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Crane
Control
Non-Destructive Testing
Sector
Upstream Oil and Gas
Link
Checked , working