Investigation Report

Crane Fast Line Broke During PVC Drain Pipe Relocation

BSEEBureau of Safety and Environmental Enforcement

03-17-2005 04:00 G01294 SP/62 Fast Line on Crane Broke

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a platform crane incident during relocation of PVC drain pipes. Failure to track the fast-line ball and malfunction of the anti-two-block system led to line breakage, dropped equipment and wrist impact from recoil. The report examines inspection-record discrepancies and documents component replacement and subsequent functional tests.

Topics

About This Record
Original title
03-17-2005 04:00 G01294 SP/62 Fast Line on Crane Broke
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Dropped Objects, Line of Fire, Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations
Equipment
Crane, Wire Rope
Control
Functional Testing, Pre-Use Checks
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-f0ad7d6b58 · added 2 October 2026