Summary

A crew member died after a provisions crane’s winch wire snapped and its pallet fork fell onto the vessel’s deck. The flash identifies a malfunctioning or missing upper limit switch and incorrectly applied U-bolt clamps, and recommends regular switch testing, correct wire terminations, pre-lift inspections and procedures addressing personnel exposure.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 09/06
Date
7 July 2006
Topic
Dropped Objects, Line of Fire, Mechanical Failure
Activity
Cargo Transfer, Inspection and Maintenance, Lifting Operations
Equipment
Crane, Lifting Accessories, Wire Rope
Control
Functional Testing, Operating and Work Procedures, Pre-Use Checks, Safety Communication