Investigation Report

Satellite Umbilical Termination Failure and Hydraulic Line Ruptures

BSEEBureau of Safety and Environmental Enforcement

11-12-2019 12:00 G32303 MC 208 Damaged/Disabled Safety Sys.SCSSV

Read at BSEEOpens the document on bsee.gov

Summary

BSEE investigates a satellite umbilical termination failure affecting the MC 208/209 subsea well. Hydraulic lines ruptured, while fail-safe shutdown successfully shut in associated wells. Findings identify excessive loading on the connection plate and failure of temporary buoyancy rigging retained for long-term use. ROV inspection and recovered-component examination informed the investigation.

Topics

About This Record
Original title
11-12-2019 12:00 G32303 MC 208 Damaged/Disabled Safety Sys.SCSSV
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Barrier Management, Loss of Containment, Mechanical Failure
Activity
Inspection and Maintenance
Sector
Upstream Oil and Gas
Setting
Subsea
Link
Checked , working
Record
bsee-fa810c6d3d · added 2 October 2026