Safety Alert

Safety Alert 136 - Air Volume Tank Explosion

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 136

Safety Alert 136 - Air Volume Tank Explosion

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

An offshore production-platform air volume tank failed when pressurised for sandblasting and painting, ejecting an end plate that struck a compressor. Inspection found incomplete weld penetration, flat rather than dished ends and extensive cracking. Despite earlier hydrostatic testing, failure occurred in service; the operator planned inspections and replacement of non-compliant vessels.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 136
Date
11 February 1985 (added from another catalogue record)
Topic
Explosion, Line of Fire, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance, Pressure Testing
Equipment
Pressure Vessel
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-safety-alert-136 · added 2 September 2026