Safety Alert

Safety Alert 145 - Tubing String Equipment Failure During a Plug and Abandonment Operation

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 145

Safety Alert 145 - Tubing String Equipment Failure During a Plug and Abandonment Operation

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

During plug and abandonment, a telescoping swivel sub parted and trapped pressure expelled approximately 500 feet of tubing. Mismatched component designs and buckled internal parts were identified. The well was controlled without injuries. Recommendations address worst-case tool testing and, whenever feasible, killing the well and bleeding trapped pressure before unseating the completion string.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 145
Date
22 August 1985 (added from another catalogue record)
Topic
Mechanical Failure, Pressure Systems, Well Control
Activity
Well Abandonment
Control
Functional Testing
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-safety-alert-145 · added 2 September 2026