Safety Alert

Safety Alert 296 - Catastrophic Failures in Mooring Systems Possibly Put Floating Structures at Risk

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 296

Safety Alert 296 - Catastrophic Failures in Mooring Systems Possibly Put Floating Structures at Risk

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

This alert examines tether-chain failure in a Gulf of Mexico hybrid riser system and earlier mooring shackle and socket failures. It discusses prohibited post-heat-treatment weld repairs, material toughness and inadequate specifications or testing. Recommendations address manufacturing inspection, qualified inspectors, representative test coupons and restrictions above buoyancy air cans.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 296
Date
12 May 2011
Topic
Mechanical Failure, Structural and Asset Integrity
Activity
Inspection and Maintenance
Equipment
Mooring Fittings, Mooring Lines
Control
Competence and Training, Exclusion Zones, Non-Destructive Testing
Sector
Upstream Oil and Gas
Setting
Offshore Installation