Safety Alert

Safety Alert - Pipeline Loss of Containment

NOPSEMANational Offshore Petroleum Safety and Environmental Management AuthorityA934641

Safety Alert - Pipeline Loss of Containment

Read at NOPSEMAOpens the document on nopsema.gov.au

Summary

A gas export pipeline tie-in spool flange failed after severe corrosion of carbon steel lacking the specified corrosion-resistant cladding. The alert examines material traceability and quality-control failures, misinterpreted inline inspection data and incorrect defect location reporting. Lessons address preserved identification, consideration of positive material identification and diverse integrity inspection measures.

Topics

About This Record
Publisher
National Offshore Petroleum Safety and Environmental Management Authority
Type
Safety Alert
Reference
A934641
Date
28 September 2023
Topic
Corrosion, Hydrocarbon Release, Mechanical Failure, Structural and Asset Integrity
Activity
Inspection and Maintenance
Equipment
Process Pipework and Pipelines
Control
Non-Destructive Testing
Sector
Upstream Oil and Gas
Setting
Offshore Installation, Subsea