Summary

BSEE reports synthetic-base mud discharge following an LMRP H-4 connector integrity failure and additional connector bolt failures. Preliminary evidence identified hydrogen-embrittlement-related stress corrosion cracking as a contributor, with improper electroplating treatment a possible cause. The alert calls for affected-bolt identification, independent certification and vendor quality-assurance reviews, including heat-treatment compliance.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 303
Date
29 January 2013
Topic
Corrosion, Loss of Containment, Mechanical Failure, Structural and Asset Integrity
Activity
Inspection and Maintenance
Equipment
Blowout Preventer
Control
Contractor Management, Independent Audit and Verification
Sector
Upstream Oil and Gas
Setting
Marine Waters