Safety Alert

Risk-Based Inspections of Subsea Leak Detection Technology Reveals Gaps in System Processes

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 407

Risk-Based Inspections of Subsea Leak Detection Technology Reveals Gaps in System Processes

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

BSEE reviews three subsea oil leaks and inspection findings showing weaknesses in leak-detection procedures and management processes. Operators and contractors are asked to consider clearer alarm response responsibilities, personnel training, system testing, configuration change control and ROV surveys. The alert emphasises investigating abnormal flow and learning from previous detection failures.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 407
Date
21 January 2021
Topic
Barrier Management, Hydrocarbon Release, Learning from Incidents
Activity
Inspection and Maintenance, ROV Operations
Equipment
Process Pipework and Pipelines
Control
Alarm Management, Competence and Training, Functional Testing, Management of Change
Sector
Upstream Oil and Gas
Setting
Subsea