Safety Alert

Ineffective Stinger Hook Pin Installation - High potential for injury and Equipment Damage

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 452

Ineffective Stinger Hook Pin Installation - High potential for injury and Equipment Damage

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

A crane stinger hook and suspended wireline lubricator fell at a Gulf of Mexico energy facility after a cotter pin sheared and the hook pin backed out. The alert identifies inadequate pin design and recommends threaded pins with nuts and keepers, retrofitting improper configurations and assessing pin condition before lifting.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 452
Date
12 December 2022
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations
Equipment
Crane, Lifting Accessories
Control
Positive Retention and Reliable Securing, Pre-Use Checks