Safety Alert

BSEE Safety Alert 494 - Ruptured Nitrogen Cylinders

BSEEBureau of Safety and Environmental EnforcementSafety Alert 494

BSEE Safety Alert 494 - Ruptured Nitrogen Cylinders

Read at BSEEOpens the document on bsee.gov

Summary

A nitrogen cylinder ruptured during preparations to pre-charge an accumulator system, causing three minor shrapnel injuries and equipment damage. BSEE attributes the failure to corrosive wall loss, aggravated by crevices, moisture and deteriorated rack coating. Recommendations address cylinder recertification, filling records, training, inspection and corrosion-preventive maintenance.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
Safety Alert 494
Date
24 January 2025 (added from another catalogue record)
Topic
Corrosion, Line of Fire, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Gas Cylinder
Control
Competence and Training, Operating and Work Procedures, Preventive Maintenance
Sector
Upstream Oil and Gas