Summary

This alert describes delayed shallow gas flows between conductor and surface casing after cementing, sometimes requiring abandonment or vessel relocation. It attributes the flows tentatively to reduced cement-column hydrostatic head and outlines logging, casing movement, slurry selection, returns monitoring and conditional retention of blowout-preventer capability.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 66
Date
26 September 1977 (added from another catalogue record)
Topic
Hydrocarbon Release, Well Control, Well Integrity
Activity
Drilling
Equipment
Blowout Preventer
Control
Operating and Work Procedures
Sector
Upstream Oil and Gas
Setting
Vessel