Summary

This case study examines the Pascagoula gas plant fires and explosions, identifying thermal fatigue in a brazed aluminium heat exchanger as the probable cause. It analyses repair history, blocked-layer venting, temperature monitoring and process safety management deficiencies, alongside emergency response and community notification. Two night-shift workers were uninjured.

Topics

About This Record
Publisher
U.S. Chemical Safety and Hazard Investigation Board
Type
Investigation Report
Date
13 February 2019
Topic
Explosion, Fire, Material Fatigue, Process Safety, Structural and Asset Integrity
Activity
Inspection and Maintenance, Pressure Testing
Control
Emergency Response, Management of Change, Pressure Relief, Risk Assessment