Safety Alert

Ear loop respirators/masks do not provide protection as tight fitting RPE

HSEUK Health and Safety ExecutiveEPD1-2022

Ear loop respirators/masks do not provide protection as tight fitting RPE

Read at HSEOpens the publisher’s page on hse.gov.uk

Summary

HSE warns against using ear-loop respirators as tight-fitting respiratory protection, including models with tightening accessories or CE and UKCA markings. Research found most failed face fit testing. The notice recommends competent fit testing during selection and asks dutyholders to review risk assessments and the suitability of their respiratory protection provision.

Topics

About This Record
Publisher
UK Health and Safety Executive
Type
Safety Alert
Reference
EPD1-2022
Date
April 2022
Topic
Respiratory Hazards
Equipment
Respirator
Control
Risk Assessment
Link
Checked , working
Record
hse-epd1-2022 · added 2 September 2026

Report a problem with this record