Safety Alert

Risk of carbon monoxide release during the storage of wood pellets

HSEUK Health and Safety ExecutiveOPSTD3-2012

Risk of carbon monoxide release during the storage of wood pellets

Read at HSEOpens the publisher’s page on hse.gov.uk

Summary

This safety alert describes fatal carbon monoxide poisoning associated with wood pellet storage, including domestic cases. It explains factors affecting gas production and oxygen depletion in enclosed stores. Suggested precautions cover competent installation and servicing, restricted entry, atmospheric checks, ventilation, risk assessment and warning information.

Topics

About This Record
Publisher
UK Health and Safety Executive
Type
Safety Alert
Reference
OPSTD3-2012
Date
5 November 2012 (added from another catalogue record)
Topic
Confined Space Hazards, Hazardous Substances, Oxygen Deficiency
Activity
Confined Space Entry, Inspection and Maintenance
Control
Competence and Training, Atmospheric Gas Testing, Risk Assessment, Ventilation
Setting
Vessel
Link
Checked , working
Record
hse-opstd3-2012 · added 2 September 2026