The dropping of a 9.5 tonne load on an offshore installation as a result of the incorrect manufacture of a 15 tonne Flemish eye crane pennant

HSEUK Health and Safety ExecutiveOSD6-2010

The dropping of a 9.5 tonne load on an offshore installation as a result of the incorrect manufacture of a 15 tonne Flemish eye crane pennant

Read at HSEOpens the publisher’s page on hse.gov.uk

Summary

An offshore lifting incident involved a 9.5-tonne container falling after an incorrectly manufactured Flemish eye crane pennant unravelled. The alert examines rope-to-ferrule compatibility and inadequate representation of dynamic loading in tests. It advises users to verify combinations and manufacturers to follow designers’ specifications, with unverified slings removed from service.

Topics

About This Record
Publisher
UK Health and Safety Executive
Type
Safety Alert
Reference
OSD6-2010
Date
10 August 2010 (added from another catalogue record)
Topic
Dropped Objects, Mechanical Failure
Activity
Lifting Operations, Rigging
Equipment
Lifting Accessories, Wire Rope
Control
Functional Testing, Operating and Work Procedures
Sector
Upstream Oil and Gas
Setting
Offshore Installation