Safety Flash

Near-miss: Falling transponder on main deck

IMCAInternational Marine Contractors AssociationIMCA SF 11/13

Near-miss: Falling transponder on main deck

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During vessel lifting operations, a whip-line transponder caught in a crane sheave as the knuckle boom folded and fell onto the deck, without injury. Investigation identified disabled or defective hook-level alarms and unfollowed change procedures. Preventive actions included removing unnecessary transponders, improving operator awareness and testing alarms at each crane start.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 11/13
Date
26 June 2013
Topic
Dropped Objects, Mechanical Failure
Activity
Lifting Operations, Rigging
Equipment
Crane, Wire Rope
Control
Alarm Management, Functional Testing, Management of Change, Operating and Work Procedures
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-11-13-near-miss-falling-transponder-on-main-deck · added 1 September 2026