Safety Alert

Additional Serious Incidents with Mismatched Hammer Unions

IADCInternational Association of Drilling ContractorsIADC Alert 00-15

Additional Serious Incidents with Mismatched Hammer Unions

Read at IADCOpens the publisher’s page on iadc.org

Summary

This alert describes two drilling-industry incidents involving mismatched 1502 male and 602 female hammer-union components. One released a union and pressure sensor from a mud-pump discharge. During a surface-casing test, another union failed at 1300 psi, below the intended 1500 psi test pressure, striking and seriously injuring a service employee.

Topics

About This Record
Publisher
International Association of Drilling Contractors
Type
Safety Alert
Reference
IADC Alert 00-15
Date
5 May 2000
Topic
Line of Fire, Mechanical Failure, Pressure Systems
Activity
Pressure Testing
Sector
Upstream Oil and Gas
Link
Checked , working
Record
iadc-alert-00-15 · added 3 September 2026