Safety Alert

Test Assembly Makeup Results in a Fatality

IADCInternational Association of Drilling ContractorsIADC Alert 04-37

Test Assembly Makeup Results in a Fatality

Read at IADCOpens the publisher’s page on iadc.org

Summary

A fatal incident occurred during pressure testing on a rig. The top-drive connection was disconnected to align a torque tube key slot and close the lower IBOP. During reconnection, the tong bite broke, allowing the test assembly to rotate and strike the worker with its side outlet and lo-torque valve.

Topics

About This Record
Publisher
International Association of Drilling Contractors
Type
Safety Alert
Reference
IADC Alert 04-37
Date
3 September 2004
Topic
Line of Fire, Mechanical Failure
Activity
Pressure Testing
Equipment
Blowout Preventer, Valve
Sector
Upstream Oil and Gas
Link
Checked , working
Record
iadc-alert-04-37 · added 3 September 2026