Pressure Trapped in Sub Sea BOP Stack DDV Solenoid Housing
Pressure Trapped in Sub Sea BOP Stack DDV Solenoid Housing
- IADC
- Safety Alert
- IADC Alert 99-38
- IsolationLine of FirePressure Systems
- Line of fireMechanical failurePressure systems
- Inspection and maintenance
- Blowout preventerValve
- Upstream oil and gas
Summary
During testing of a subsea BOP stack, the blue pod’s shear accumulator failed to charge and a faulty DDV was suspected. Its solenoid housing was tilted, with four bolts sheared. Removing the remaining two bolts to investigate caused the housing top to fly into a bulkhead.
Classifications: Line of fire; struck-by hazards.
Classifications: Mechanical failure; equipment failure.
Classifications: Pressure systems; stored pressure; pressurised systems; pressurized systems.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Blowout preventer; BOP; blow-out preventer.
Classifications: Valve; valves.
Classifications: Upstream oil and gas; oil and gas extraction; upstream petroleum.
Summary
Hazards from pressure trapped inside a subsea blowout preventer solenoid housing.
IADC Alert 99-38. Themes: isolation, line of fire, pressure systems.