Safety Alert

Trapped Pressure in Annular Results in a Near Miss

IADCInternational Association of Drilling ContractorsIADC Alert 03-51

Trapped Pressure in Annular Results in a Near Miss

Read at IADCOpens the publisher’s page on iadc.org

Summary

A near miss during maintenance of a 13 5/8-inch 10K annular blowout preventer involved sudden cap ejection while a second pull-down bolt was being removed. The cap rose 4–5 ft, landing slightly off centre on the assembly. Three remaining bolts sheared; no personnel were injured.

Topics

About This Record
Publisher
International Association of Drilling Contractors
Type
Safety Alert
Reference
IADC Alert 03-51
Date
7 December 2003
Topic
Line of Fire, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Blowout Preventer
Sector
Upstream Oil and Gas
Link
Checked , working
Record
iadc-alert-03-51 · added 3 September 2026