Safety Alert
Dropped Object – Casing High Potential Near Miss
Read at IADCOpens the publisher’s page on iadc.org
Summary
This alert describes a casing-handling near miss involving a single joint elevator and a long pick-up assembly connected to the top drive. The casing caught on a derrick brace or roller, both sling links parted, and the joint slid down the V-door to the catwalk end. No injuries were reported.