Safety Flash

High potential dropped object

IMCAInternational Marine Contractors AssociationIMCA SF 01/15

High potential dropped object

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During vessel pipe spooling, a 60 kg Hilman roller chain fell 10 m after a link plate failed. No injuries occurred, but a detached 2 kg roller landed outside the barriers. The flash discusses secondary retention, thorough pre-use inspections, dropped-object sweeps and barrier positioning that accounts for rebounds. The failure’s cause remained unidentified.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 01/15
Date
16 January 2015
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance
Control
Exclusion Zones, Positive Retention and Reliable Securing, Pre-Use Checks, Risk Assessment
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-01-15-high-potential-dropped-object · added 1 September 2026