Safety Flash

Galley equipment broke free of fastenings during severe weather

IMCAInternational Marine Contractors AssociationIMCA SF 02/07

Galley equipment broke free of fastenings during severe weather

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A vessel’s galley grill fryer toppled during a severe storm, narrowly missing a steward without injury. Investigation found securing bolts attached only to tiles rather than the steel deck. The flash describes evacuation, electrical isolation, temporary sea-fastening, checks of other appliances and secure reinstallation after the weather abated.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 02/07
Date
12 March 2007
Topic
Line of Fire, Mechanical Failure, Structural and Asset Integrity
Activity
Electrical Isolation, Inspection and Maintenance
Control
Evacuation, Escape and Rescue, Energy and Process Isolation, Positive Retention and Reliable Securing
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-02-07-galley-equipment-broke-free-of-fastenings-during-severe-weather · added 1 September 2026