Safety Flash

Use of spelter sockets

IMCAInternational Marine Contractors AssociationIMCA SF 02/08

Use of spelter sockets

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A diving bell guide weight detached from a wire-rope termination aboard a dive support vessel, requiring subsea ROV intervention for recovery. The load-pin detachment mechanism remained unknown. The flash encourages closed sockets where possible and recommends screwed pins with nuts and split cotter pins for subsea lifting or exposure to side impact.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 02/08
Date
4 February 2008
Topic
Dropped Objects, Mechanical Failure
Activity
Diving Operations, Rigging
Equipment
Lifting Accessories, Wire Rope
Control
Positive Retention and Reliable Securing
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-02-08-use-of-spelter-sockets · added 1 September 2026