Safety Flash

Fatality during anchor handling operation

IMCAInternational Marine Contractors AssociationIMCA SF 02/10

Fatality during anchor handling operation

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A fatal anchor-recovery incident aboard a tug involved a buoy striking two crew members after a worn, oversized wire-stopper insert failed to restrain the pennant. Incorrect anchor-position information contributed to unexpected tension. Recommendations address stopper compatibility, monthly maintenance checks, survey-screen information and warnings, and a dedicated watch during recovery.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 02/10
Date
8 April 2010
Topic
Human Factors, Line of Fire, Mechanical Failure
Activity
Anchor Handling, Inspection and Maintenance
Equipment
Operator Displays and Control Interfaces, Wire Rope
Control
Operational Supervision, Preventive Maintenance
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-02-10-fatality-during-anchor-handling-operation · added 1 September 2026

Report a problem with this record