Summary

An oxygen–acetylene cutting hose burst and burned during torch ignition, without injuries. Inspection found brittle, perished hoses; an inoperative non-return valve was suspected, and connections had not been leak checked. The flash explains flashback hazards and recommends suitable leak detection, equipment inspection, correct lighting procedures and flashback arresters.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 02/14
Date
20 February 2014
Topic
Explosion, Fire, Mechanical Failure
Activity
Hot Work, Inspection and Maintenance
Equipment
Gas Cylinder, Hose, Valve
Control
Fire Protection, Operating and Work Procedures, Pre-Use Checks, Preventive Maintenance