Safety Flash

Three bolts sheared on a lifting trunnion

IMCAInternational Marine Contractors AssociationIMCA SF 02/22

Three bolts sheared on a lifting trunnion

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

Following offshore renewables transition-piece installation, a 44 kg lifting-trunnion cover plate fell approximately 0.5 m when three securing screws sheared. The flash identifies an incorrect assumption about sideways loading in screw verification, records work-planning safeguards used, and calls for welding cover plates to the trunnions.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 02/22
Date
20 January 2022
Topic
Dropped Objects, Mechanical Failure, Structural and Asset Integrity
Activity
Lifting Operations
Equipment
Lifting Accessories
Control
Job Safety Analysis, Permit to Work, Positive Retention and Reliable Securing, Risk Assessment
Sector
Offshore Wind
Link
Checked , working
Record
imca-sf-02-22-three-bolts-sheared-on-a-lifting-trunnion · added 1 September 2026

Report a problem with this record