Safety Flash
Three bolts sheared on a lifting trunnion
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
Following offshore renewables transition-piece installation, a 44 kg lifting-trunnion cover plate fell approximately 0.5 m when three securing screws sheared. The flash identifies an incorrect assumption about sideways loading in screw verification, records work-planning safeguards used, and calls for welding cover plates to the trunnions.