Safety Flash

High potential near miss: Guide cone funnel dropped

IMCAInternational Marine Contractors AssociationIMCA SF 27/19

High potential near miss: Guide cone funnel dropped

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A guide cone funnel weighing approximately 500 kg fell more than 4 m towards moonpool doors during lifting of an umbilical termination head. The flash identifies unsuitable locking for vertical installation and gaps in design review and contractor coordination. Recommendations address secondary securing, revised instructions and participation in hazard reviews.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 27/19
Date
22 November 2019
Topic
Dropped Objects, Mechanical Failure, Structural and Asset Integrity
Activity
Lifting Operations
Control
Contractor Management, Operating and Work Procedures, Positive Retention and Reliable Securing, Risk Assessment
Link
Checked , working
Record
imca-sf-27-19-high-potential-near-miss-guide-cone-funnel-dropped · added 1 September 2026