Summary

A saturation diver working in 120 m of water was struck by an ascending pipeline lay-down head during lift-bag preparations. The flash identifies inaccurate weight data use, inadequate communication, disconnected safety arrangements and insufficient change assessment. Recommendations address measured load weights, lift planning, diving procedures and escalation of safety-device changes.