Safety Flash

Crane motion reference unit (MRU) malfunctions after overheating

IMCAInternational Marine Contractors AssociationIMCA SF 03/11

Crane motion reference unit (MRU) malfunctions after overheating

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During FPSO mooring-chain inspection, a crane unexpectedly left active heave compensation mode and paid out approximately three to four metres of wire. An overheated motion reference unit supplied spurious signals, triggering shutdown. The flash describes cooling improvements, an air-conditioning trip alarm and start-up inspection, alongside further measures considered.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 03/11
Date
1 April 2011
Topic
Functional Safety
Activity
Inspection and Maintenance, Lifting Operations
Equipment
Crane
Control
Alarm Management, Pre-Use Checks, Risk Assessment
Sector
Upstream Oil and Gas
Setting
Vessel
Link
Checked , working
Record
imca-sf-03-11-crane-motion-reference-unit-mru-malfunctions-after-overheating · added 1 September 2026