Safety Flash
Near miss: Diver's umbilical drawn beneath a load
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A diver’s umbilical was drawn beneath a GRP cover by suction during rigging hook-up. Vessel heave unexpectedly lifted the cover while crane active heave compensation was in use. The soft seabed prevented damage, with no service interruption or injuries. The risk assessment had not identified this umbilical movement hazard.