Summary
This safety flash describes a scaffolder falling after a supporting vertical tube slipped through its coupler. Nearby workers could not tighten the connection in time. An inertia reel harness arrested the fall, while the scaffolder retained the tube and remained suspended over water for approximately seven minutes.
Classifications: Falls from height; fall from height.
Classifications: Working at height; work at height.
Classifications: Fall protection equipment; safety harness; fall arrest equipment.
Classifications: Scaffold; scaffolding.
Summary
The National Offshore Petroleum Safety and Environmental Management Authority of Australia (NOPSEMA) has published a report regarding an incident in which a vertical scaffolding tube (a ‘dropper’) supporting a scaffolder began to slip under his weight.