Safety Flash

Near-miss: Internal bell door

IMCAInternational Marine Contractors AssociationIMCA SF 05/04

Near-miss: Internal bell door

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A corroded hydraulic fitting failed during a dive, allowing the bell’s inner door to fall shut and narrowly miss the bellman’s feet. The flash highlights stainless-steel pipes and fittings, automatic gravity-driven latching rather than manual primary securing, and company instructions to inspect door arrangements and identify rectification programmes.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 05/04
Date
1 June 2004
Topic
Corrosion, Dropped Objects, Mechanical Failure
Activity
Diving Operations, Inspection and Maintenance
Equipment
Diving Bell
Control
Positive Retention and Reliable Securing, Safety Communication
Sector
Marine Industry
Link
Checked , working
Record
imca-sf-05-04-near-miss-internal-bell-door · added 1 September 2026