Summary

A hinged A-frame platform failed during sheave-block load checks aboard a vessel alongside for mobilisation, leaving a crew member suspended in their harness with minor injuries. The flash identifies missing cotter pins, hinge design flaws and galvanic corrosion, alongside omitted change management, scheduled maintenance and platform inspections.