Safety Flash

USCG: Corrosion causing structural failure on accommodation ladders

IMCAInternational Marine Contractors AssociationIMCA SF 29/21

USCG: Corrosion causing structural failure on accommodation ladders

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

This flash summarises a USCG alert about corrosion of accommodation ladder turntable pins. A pin failed during ladder stowage, causing a crew member to fall approximately 30 feet and suffer serious injuries. The Coast Guard strongly recommends pin maintenance, periodic inspection, replacement when necessary and inclusion in ladder maintenance plans.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 29/21
Date
28 October 2021
Topic
Corrosion, Falls from Height, Mechanical Failure, Structural and Asset Integrity
Activity
Inspection and Maintenance, Marine Operations
Equipment
Ladder
Control
Preventive Maintenance
Sector
Marine Industry
Setting
Vessel