Safety Flash

Staphylococcal infection in deep water saturation dive to 200 metres

IMCAInternational Marine Contractors AssociationIMCA SF 05/04

Staphylococcal infection in deep water saturation dive to 200 metres

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

This flash describes staphylococcal infection affecting seven saturation divers, including one during decompression, while the team worked at approximately 200 metres. The member identified limited isolation capacity, shared chin pads, helmet rotation, high humidity, hygiene shortcomings and insufficiently stringent pre-saturation medicals as factors in its spread.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 05/04
Date
1 June 2004
Topic
Occupational Health
Activity
Saturation Diving
Equipment
Personal Protective Equipment
Control
Fitness Assessment
Setting
Vessel
Link
Checked , working
Record
imca-sf-05-04-staphylococcal-infection-in-deep-water-saturation-dive-to-200-metres · added 1 September 2026