Safety Flash

High potential near-miss during equipment testing

IMCAInternational Marine Contractors AssociationIMCA SF 05/13

High potential near-miss during equipment testing

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A forklift used to tension an electrical cable remained connected to a worktable after testing. A subsequent operator drove away, dragging the table approximately one metre before stopping. Nobody was injured. Findings highlighted missing procedures and job safety analysis, poor communication and omitted vehicle checks.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 05/13
Date
4 April 2013
Topic
Human Factors, Line of Fire
Activity
Electrical Work, Vehicles and Driving
Control
Job Safety Analysis, Operating and Work Procedures, Pre-Use Checks, Safety Communication