Safety Flash

Near miss: Diver reports tight gas

IMCAInternational Marine Contractors AssociationIMCA SF 05/19

Near miss: Diver reports tight gas

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A diver switched to bailout and returned to the submersible diving chamber after experiencing restricted gas supply. Internal valves secured during a delay had not been restored following completed checks. The flash highlights checklist timing, recording deviations and repeating valve checks before operations recommence, alongside formal review of habitual procedural changes.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 05/19
Date
20 March 2019
Topic
Human Factors
Activity
Diving Operations
Equipment
Diving Bell, Valve
Control
Management of Change, Operating and Work Procedures, Pre-Use Checks, Safety Communication