Summary

During riser recovery at sea, a 3.8-tonne section fell approximately 2.5 m onto the deck after sharp deadman-anchor edges cut its soft slings. Personnel remained behind barriers. The flash recommends wire rope slings, subject to a risk-assessed exception, and consideration of rounded anchors or welded pad eyes.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 05/21
Date
11 February 2021
Topic
Dropped Objects, Mechanical Failure
Activity
Decommissioning, Lifting Operations, Rigging