Safety Flash

Leaking oxygen valve

IMCAInternational Marine Contractors AssociationIMCA SF 06/05

Leaking oxygen valve

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A diver’s cutting torch leaked oxygen on the seabed at around 27 msw, despite showing no leak during surface testing. The flash attributes this to the valve housing fit under ambient pressure at depth. Recommendations cover topside leak testing, housing seating and set-screw adjustment, vendor communication and inspection documentation.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 06/05
Date
2 May 2005
Topic
Loss of Containment, Pressure Systems
Activity
Diving Operations, Inspection and Maintenance
Equipment
Hand Tools, Valve
Control
Functional Testing, Pre-Use Checks, Safety Communication
Setting
Subsea
Link
Checked , working
Record
imca-sf-06-05-leaking-oxygen-valve · added 1 September 2026